Mark 50/501/502/51 Series – Self-Operated

Mark 50/501/502/51 Series – Self-Operated

The Mark 50 Sliding Gate Back Pressure Regulator is used to regulate upstream pressure at a predetermined setpoint. The spring in the Mark 50 holds the sliding gate seats in their normally closed position.

Upstream pressure is sensed beneath the diaphragm. As the upstream pressure exceeds the setpoint, pressure is exerted on the diaphragm compressing the spring, which raises the stem to modulate the disc (the moveable component of the sliding gate seat set) toward the open position. As the seats open, upstream pressure is regulated to the required setpoint. A decrease in pressure relaxes the spring and diaphragm, moving the seats toward the closed position.